TCX® ( C ) 331 150/250V 10T1.5

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TCX® (C) 331  150/250 V fire resistant armoured  twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables show a low transfer impedance in low frequency and an effective screening in high frequency, making them very suitable for polluted electromagnetic surroundings. TCX(C) 331  cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

 

Design

  1. Conductor:
    Stranded bare copper
    Class 2

  2. Insulation:
    Mica tape + XLPE (cross-linked polyethylene)
    Optional: Special fire resistant HF 90 (halogen-free compound)
    with INFITTM technology

  3. Inner covering:
    Lapped polyester tape

  4. Armouring:
    Bare copper braid

  5. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: orange

Marking

I NEXANS I TCX (C) 331 150/250 V  "n" 2 or 3 "s" mm²  90°C IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2  "ww/yy" * CE * TCF + metric marking

 

Core identification

  • Core 1 : white
  • Core 2 : blue
  • Core 3: red
  • Double identification: pair and conductor

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor flexibility
Stranded class 2
Insulation
HFFR special
Outer sheath
Polyolefin
Conductor material
Bare copper
Sheath colour
Orange
Armour type
Bare copper braid
Drain wire
Tinned copper
Protection
Polyester tape(s)

Dimensional characteristics

Dimensional characteristics

Number of pairs
-
Number of triples
10
Conductor cross-section
1.5 mm²
Nominal outer diameter
29.7 mm
Minimum outer diameter
28.5 mm
Maximum outer diameter
32.0 mm
Approximate weight
1050 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
150 / 250 (300) V
Max. DC resistance of the conductor at 20°C
25.6 Ohm/km

Usage characteristics

Usage characteristics

Standard
IEC
Fire retardant
EN IEC 60332-3-22 (cat A)
Fire resistant
IEC 60331-21, IEC 60331-1 or 2
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C
Midspan
-
Water proof
-

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close